Board Mount Current Sensors

Results: 2.578
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Response Time Accuracy Frequency Range Operating Supply Voltage Output Type Qualification
LEM Board Mount Current Sensors Current Transducer HLSR-P series

50 A Open Loop 2.5 us 0.5 % 400 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Integrated Current Sensor HMSR-SMS series.

10 A Open Loop 0.75 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Integrated Current Sensor HMSR-SMS series

15 A Open Loop 0.75 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Integrated Current Sensor HMSR-SMS series

20 A Open Loop 0.75 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Integrated Current Sensor HMSR-SMS series

6 A Open Loop 0.75 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Integrated Current Sensor HMSR-SMS series

8 A Open Loop 0.75 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer HOB-P series

50 A Open Loop 200 ns 0.75 % 1 MHz 5 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer HOB-P/SP1 series

50 A Open Loop 200 ns 0.75 % 1 MHz 5 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LA 100-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

100 A Closed Loop 1 us 0.7 % 200 kHz 12 V, 15 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LA 200-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

200 A Closed Loop 1 us 0.65 % 200 kHz 12 V, 15 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LES series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation betweenthe primary and the secondary circuit.

15 A Closed Loop 400 ns 0.7 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LESR series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation betweenthe primary and the secondary circuit.

6 A Closed Loop 400 ns 0.75 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LKSR series

50 A Closed Loop 400 ns 0.7 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Voltage Transducer LV 25-P For the electronic measurement of voltages: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

8 mA Closed Loop 40 us 0.9 % 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LXS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation betweenthe primary and the secondary circuit.

25 A Closed Loop 400 ns 3 % 300 kHz 5 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LZSR 200-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit.

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
KEMET Board Mount Current Sensors 250mV Max 4.5mA to 50mA 8 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200

13 mA Open Loop 280 ms 55 Hz 5 V Digital, Analog AEC-Q200
KEMET Board Mount Current Sensors 250mV Max 5.0mA to 50mA 9 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200

13 mA Open Loop 200 ms 55 Hz 5 V Analog AEC-Q200
KEMET Board Mount Current Sensors 250mV Max 4.5mA to 50mA 10 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200

13 mA Open Loop 280 ms 55 Hz 5 V Digital, Analog AEC-Q200
KEMET Board Mount Current Sensors 250mV Max 4.5mA to 50mA 6 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200

13 mA Open Loop 280 ms 55 Hz 5 V Digital, Analog AEC-Q200
KEMET Board Mount Current Sensors 250mV Max 5.0mA to 50mA 7 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200

13 mA Open Loop 200 ms 55 Hz 5 V Analog AEC-Q200
KEMET Board Mount Current Sensors 250mV Max 4.5mA to 50mA 12 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200

13 mA Open Loop 280 ms 55 Hz 5 V Digital, Analog AEC-Q200
KEMET Board Mount Current Sensors 250mV Max 5.0mA to 50mA 13 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200

13 mA Open Loop 200 ms 55 Hz 5 V Analog AEC-Q200
Allegro MicroSystems ACS720KLATR-80AB-T
Allegro MicroSystems Board Mount Current Sensors INTEGRATED CURRENT SENSOR WITH DIGITAL TEMPERATURE COMPENSATION

Allegro MicroSystems ACS725LLCTR-05AB-S
Allegro MicroSystems Board Mount Current Sensors CURRENT SENSOR